N_031.mp4 May 2026
: Fully retract the boom. Turn the potentiometer counter-clockwise until it stops to reset the "zero" point.
: Test that the system successfully disables crane functions during an overload condition. n_031.mp4
: Ensure the hoist limit switch stops the winch before the hook hits the boom tip. : Fully retract the boom
: Remove old wires from the terminal block and connect the new assembly. n_031.mp4
Before completing the assembly, verify these digital inputs:
Detailed wiring diagrams and flowcharts can be found in the PAT DS350 Service Manual or via WIKA Mobile Control Support . LENGTH-ANGLE-RADIUS-LOAD INDICATING SYSTEM